Function features. 
1. Pre-payment mode, purchase electricity first and then use electricity. 
2. Use encryption card, and the password is unique. 
3. Has two classes power shortage alarming function, reminding the user to purchase electricity in time. 
4. Automatic power off due to excessive load. Record the number of excessive load, preventing miss over loading when the capacitive load starts. 
5. Electricity stealing prevention, automatically record illegal electricity consumption. 
6. ...
CE Approved Single Phase Prepayment Energy Meter  2008-03-19 [China]  >> Expired
Function features. 1. Pre-payment mode, purchase electricity first and then use electricity. 2. Use encryption card, and the password is unique. 3. Has two classes power shortage alarming function, reminding the user to purchase electricity in time. 4. Automatic power off due to excessive load. Record the number of excessive load, preventing miss over loading when the capacitive load starts. 5. Electricity stealing prevention, automatically record illegal electricity consumption. 6. ...   >>
Add to My20un | User's Products | User's Profile | Contact
This kind of meter can be installed GPRS module (installed inside or providing outside), wireless module, GSM module and solving the remote meter reading channel according to the requirement of the customer. It expands the function of the meter. 

Main Functions 

11. Measuring function: Measuring electricity, measuring demand, measuring voltage, current and power, and measuring power factor function. 

2. Alarming missing voltage, missing current and displaying and recording function. 
...
Multi-Function Energy Meter (Single DDSY1286)  2008-03-19 [China]  >> Expired
This kind of meter can be installed GPRS module (installed inside or providing outside), wireless module, GSM module and solving the remote meter reading channel according to the requirement of the customer. It expands the function of the meter. Main Functions 11. Measuring function: Measuring electricity, measuring demand, measuring voltage, current and power, and measuring power factor function. 2. Alarming missing voltage, missing current and displaying and recording function. ...   >>
Add to My20un | User's Products | User's Profile | Contact
Summarize
FYLTH-PS  Portable Single-phase kwh Meter Test Bench is a semi-automatic device designed according to the national standards and regulations.This device is composed of single-phase power supply and wide-range standard power watt-hour meter.It is of high accuracy, wide rang and light weight, and it can be easily operated.It can be used not only in the testing room, but on-site, and can test or check the single-phase electronic or inductive watt-hour meter under 1.0.

Main technical p...
Portable Single-Phase KWH Meter Test Bench  2008-03-19 [China]  >> Expired
Summarize FYLTH-PS Portable Single-phase kwh Meter Test Bench is a semi-automatic device designed according to the national standards and regulations.This device is composed of single-phase power supply and wide-range standard power watt-hour meter.It is of high accuracy, wide rang and light weight, and it can be easily operated.It can be used not only in the testing room, but on-site, and can test or check the single-phase electronic or inductive watt-hour meter under 1.0. Main technical p...   >>
Add to My20un | User's Products | User's Profile | Contact
Main technical parameters
1 Accuracy of test bench: 0.1/0.2
 Accuracy of standard meter: 0.1/0.2
2Accuracy of monitoring meter (digital displayed): 
 Voltage/current/power meter: 0.5% 
(Equipped with electronic compensated voltage power source)
3Input voltage: AC 3*380V/220V 50Hz
4Straight current range of regulation: 150mA\× a% 0~120% continuously
5Adjustment range & step as per the attached table
Three-Phase Kwh Meter Test Bench (Semi-Automatic)  2008-03-19 [China]  >> Expired
Main technical parameters 1 Accuracy of test bench: 0.1/0.2 Accuracy of standard meter: 0.1/0.2 2Accuracy of monitoring meter (digital displayed): Voltage/current/power meter: 0.5% (Equipped with electronic compensated voltage power source) 3Input voltage: AC 3*380V/220V 50Hz 4Straight current range of regulation: 150mA\× a% 0~120% continuously 5Adjustment range & step as per the attached table   >>
Add to My20un | User's Products | User's Profile | Contact
Summarize
FYLTH-PA Portable Single-phase Watt-hour Programmable Test Bench is a full-automatic device designed according to the national standard and regulations. It is composed of single-phase power source, withdrawing wide-range standard power watt-hour meter and error calculator. Comparative testing is applied so that three electronic or inductive single-phase watt-hour meters can be calibrated at one time. With big LCD screen, it is user-friendly; With high accuracy and wide range, it can b...
Portable Single-phase Kwh Meter Programmable Test Bench  2008-03-19 [China]  >> Expired
Summarize FYLTH-PA Portable Single-phase Watt-hour Programmable Test Bench is a full-automatic device designed according to the national standard and regulations. It is composed of single-phase power source, withdrawing wide-range standard power watt-hour meter and error calculator. Comparative testing is applied so that three electronic or inductive single-phase watt-hour meters can be calibrated at one time. With big LCD screen, it is user-friendly; With high accuracy and wide range, it can b...   >>
Add to My20un | User's Products | User's Profile | Contact
Main technical parameters
1 Accuracy grade and configuration: 
 Accuracy of test bench: 0.05/0.1/0.2
 Configuration of standard meter: 0.05/0.1/0.2
2 Accuracy level of monitoring instrument: 
(digital type)Voltage &Current & Power: ± 0.5%
Phase: ± 1° 
Frequency: ± 0.1HZ
3 Input Voltages: 220V, 50HZ
4 Output power: Voltage loop > 750VA
 Current loop > (24, 48 loops)
5 Stability of output voltage, current and power: 
≤0.05%(PF=1, 3 min)
6 Waveform distortion of output voltage: â...
Single-Phase kWh Meter Programmable Test Bench  2008-03-19 [China]  >> Expired
Main technical parameters 1 Accuracy grade and configuration: Accuracy of test bench: 0.05/0.1/0.2 Configuration of standard meter: 0.05/0.1/0.2 2 Accuracy level of monitoring instrument: (digital type)Voltage &Current & Power: ± 0.5% Phase: ± 1° Frequency: ± 0.1HZ 3 Input Voltages: 220V, 50HZ 4 Output power: Voltage loop > 750VA Current loop > (24, 48 loops) 5 Stability of output voltage, current and power: ≤0.05%(PF=1, 3 min) 6 Waveform distortion of output voltage: â...   >>
Add to My20un | User's Products | User's Profile | Contact
Performance criteria: 

Operating humidity 	≤ 75%
Storage humidity 	≤ 95%
Operating temperature 	-10C - +50C
Storage temperature 	-30C - +70C
International standard		 	IEC 62053-21
Accuracy class		 1
Protection against penetration 
Of dust and water IP51
Insulating encased meter of 
Protective class II

Specifications: 
Meter type DRS201A(register display) 
DRS201D LCD (LCD display)
Nominal voltage (Un) 230V AC
Operational voltage	 161 - 300V AC
Insulation capabilities: 	
...
Single Phase Rail Energy Meter (DRS201)  2008-03-19 [China]  >> Expired
Performance criteria: Operating humidity ≤ 75% Storage humidity ≤ 95% Operating temperature -10C - +50C Storage temperature -30C - +70C International standard IEC 62053-21 Accuracy class 1 Protection against penetration Of dust and water IP51 Insulating encased meter of Protective class II Specifications: Meter type DRS201A(register display) DRS201D LCD (LCD display) Nominal voltage (Un) 230V AC Operational voltage 161 - 300V AC Insulation capabilities: ...   >>
Add to My20un | User's Products | User's Profile | Contact
Function features. 
1. Pre-payment mode, purchase electricity first and then use electricity. 
2. Use encryption card, and the password is unique. 
3. Has two classes power shortage alarming function, reminding the user to purchase electricity in time. 
4. Automatic power off due to excessive load. Record the number of excessive load, preventing miss over loading when the capacitive load starts. 
5. Electricity stealing prevention, automatically record illegal electricity consumption. 
6. ...
CE Approved Single Phase Prepayment Energy Meter  2008-01-23 [China]  >> Expired
Function features. 1. Pre-payment mode, purchase electricity first and then use electricity. 2. Use encryption card, and the password is unique. 3. Has two classes power shortage alarming function, reminding the user to purchase electricity in time. 4. Automatic power off due to excessive load. Record the number of excessive load, preventing miss over loading when the capacitive load starts. 5. Electricity stealing prevention, automatically record illegal electricity consumption. 6. ...   >>
Add to My20un | User's Products | User's Profile | Contact
1 Type		Socket Meter	
2 Accuracy		1	
3 Reference voltage	 3*220/380V (or 3*110/220V)	
4 Range of working voltage	0.9Un~1.1Un
5 Referece frequency		50Hz (or 60Hz)	
6 Connect		3 Phase 4 Wires	
7 Reference current		20(100)A	
8 Constant of meter		800imp/kWh (or Other)	
9 Starting current		0.4%Ib	
10 Working temperature		-25C~65C	
11 Storage temperature		-40C~75C
12 Relative humidity		85% (or up to 95%)	
31 Display		LCD	
13 Standard		IEC 1036	Maximum and Minimum parameters				
14 Maximu...
Socket Type Energy Meter  2008-01-23 [China]  >> Expired
1 Type Socket Meter 2 Accuracy 1 3 Reference voltage 3*220/380V (or 3*110/220V) 4 Range of working voltage 0.9Un~1.1Un 5 Referece frequency 50Hz (or 60Hz) 6 Connect 3 Phase 4 Wires 7 Reference current 20(100)A 8 Constant of meter 800imp/kWh (or Other) 9 Starting current 0.4%Ib 10 Working temperature -25C~65C 11 Storage temperature -40C~75C 12 Relative humidity 85% (or up to 95%) 31 Display LCD 13 Standard IEC 1036 Maximum and Minimum parameters 14 Maximu...   >>