Buy  
Home | Sign In | Register | View basket
 

Wenzhou Kangyu Electrical Co.,Ltd.
 

All Trade Leads by Wenzhou Kangyu Electrical Co.,Ltd.

Contact Select All Clear All
HL32-100 Isolating Switches
Having superior dynamic-heating ability,it is mainly used as a main switch for both terminal assembly electric equipment case,and illumination assembly case,and to control various motors and small power electric equipment as well,it has to no function of protection of  overload short-circuit.
HL32-100 Isolating Switches  2005-03-10 [China]  >> Expired
HL32-100 Isolating Switches Having superior dynamic-heating ability,it is mainly used as a main switch for both terminal assembly electric equipment case,and illumination assembly case,and to control various motors and small power electric equipment as well,it has to no function of protection of overload short-circuit.   >>
Add to My20un | User's Products | User's Profile | Contact
DZ�PHASE+NEUTRAL�CIRCUIT BREAKER
The products is applicable to protect line conductor and overload,and short circuit of small sealed motors.It is mainly for protection of circuits with AC 220V and 50Hz/60Hz,and for unfrequent conversion under normal conditions as well.Its action can be up to two poles with its only one pole volume and be used as a leakage breaker by assembling with leakage.It is produced as per EN898-87,IEC947-2 standards.
Technical data
1.	Current rating:1,2,3,4,6,10,20,...
DZâ€?PHASE+NEUTRALâ€?CIRCUIT BREAKER  2005-03-10 [China]  >> Expired
DZâ€?PHASE+NEUTRALâ€?CIRCUIT BREAKER The products is applicable to protect line conductor and overload,and short circuit of small sealed motors.It is mainly for protection of circuits with AC 220V and 50Hz/60Hz,and for unfrequent conversion under normal conditions as well.Its action can be up to two poles with its only one pole volume and be used as a leakage breaker by assembling with leakage.It is produced as per EN898-87,IEC947-2 standards. Technical data 1. Current rating:1,2,3,4,6,10,20,...   >>
Add to My20un | User's Products | User's Profile | Contact
DZ47-63(C45N) Series Mini Circuit Breaker
C45N series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system.The product is neoteric in structure,light in weight,reliable and execllent in performance.Its frame and parts adopt plastics of high fire-resistant and shockproof.The product,with long life,is mainly used in AC 50/60Hz single-pole 240V or two,three,four-pole 415V circuit for overload and short-circuit ...
DZ47-63(C45N) Series Mini Circuit Breaker  2005-03-10 [China]  >> Expired
DZ47-63(C45N) Series Mini Circuit Breaker C45N series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short-circuit in the system.The product is neoteric in structure,light in weight,reliable and execllent in performance.Its frame and parts adopt plastics of high fire-resistant and shockproof.The product,with long life,is mainly used in AC 50/60Hz single-pole 240V or two,three,four-pole 415V circuit for overload and short-circuit ...   >>
Add to My20un | User's Products | User's Profile | Contact
DXTM Mini Circuit Breaker (Legrand Model)
This product is a kind of mini Circuit breaker of Legrand model.  
Breaking Capacity : 6000A
Rated Voltage : 230V/400V
Rated Current : 1,3,6,10,16,20,25,32,40,50,63(A)
Standard : IEC898
Pole No. : 1,2,3
DXTM Mini Circuit Breaker (Legrand Model)  2005-03-10 [China]  >> Expired
DXTM Mini Circuit Breaker (Legrand Model) This product is a kind of mini Circuit breaker of Legrand model. Breaking Capacity : 6000A Rated Voltage : 230V/400V Rated Current : 1,3,6,10,16,20,25,32,40,50,63(A) Standard : IEC898 Pole No. : 1,2,3   >>
Add to My20un | User's Products | User's Profile | Contact
BH Mini Circuit Breaker	
BH series mini circuit breaker is characteristics of small size,light weight,novel struture and excellent performance.They are mounted in the illuminating distribution board and used in guesthouse,block of flats,high buildings,square,airports,railway stations,plants and enterprise etc,in AC circuits 240V(single pole)up to 415V(3 pole)50Hz for protection of overload short circuit and for circuit changover in lighting system.Breaking capacity is 3KA.The items comply with ...
BH Mini Circuit Breaker  2005-03-10 [China]  >> Expired
BH Mini Circuit Breaker BH series mini circuit breaker is characteristics of small size,light weight,novel struture and excellent performance.They are mounted in the illuminating distribution board and used in guesthouse,block of flats,high buildings,square,airports,railway stations,plants and enterprise etc,in AC circuits 240V(single pole)up to 415V(3 pole)50Hz for protection of overload short circuit and for circuit changover in lighting system.Breaking capacity is 3KA.The items comply with ...   >>
Add to My20un | User's Products | User's Profile | Contact
3TB AC Contactor
The contactor is suitable for using in the circuits up to rated voltage 660V AC 50Hz or 60 Hz,rated current 630A,for making and breaking,and for frequent starting and controlling the motor.After combined with the mechanical interlocking device,it becomes 3TD series convertible contactor for controlling,starting,breaking and reversing of the motor.The products comply with IEC947-2 & VDE0660.
3TB AC Contactor  2005-03-10 [China]  >> Expired
3TB AC Contactor The contactor is suitable for using in the circuits up to rated voltage 660V AC 50Hz or 60 Hz,rated current 630A,for making and breaking,and for frequent starting and controlling the motor.After combined with the mechanical interlocking device,it becomes 3TD series convertible contactor for controlling,starting,breaking and reversing of the motor.The products comply with IEC947-2 & VDE0660.   >>
Add to My20un | User's Products | User's Profile | Contact
3TD Mechanical Interlocking Contactor	
The contactor is suitable for using  in the circuits up to the rated voltage 660V AC 50Hz or 60Hz,current 330A,for convertible controlling the motor.It’s mechanical interlocking device ensures contact changeover of the two convertible contactors.
3TD Mechanical Interlocking Contactor  2005-03-10 [China]  >> Expired
3TD Mechanical Interlocking Contactor The contactor is suitable for using in the circuits up to the rated voltage 660V AC 50Hz or 60Hz,current 330A,for convertible controlling the motor.It’s mechanical interlocking device ensures contact changeover of the two convertible contactors.   >>
Add to My20un | User's Products | User's Profile | Contact
3TF AC Contactor
Application
3TF series AC Contactor are suitable in ectrical system with AC50/60Hz,ratedoperatioinal voltage up to 660V.In AC-3 usage,rated operational voltage u to 380V,rated operational current up to 630A to make or break remote motors or system.they can form electromagnetic starters with suitable thermal overload relays 3UA series to protect system and motors against overload or phase-failure.They are made according to IEC947-2,BS5424 & VDE0660.
The contactor is a straight...
3TF AC Contactor  2005-03-10 [China]  >> Expired
3TF AC Contactor Application 3TF series AC Contactor are suitable in ectrical system with AC50/60Hz,ratedoperatioinal voltage up to 660V.In AC-3 usage,rated operational voltage u to 380V,rated operational current up to 630A to make or break remote motors or system.they can form electromagnetic starters with suitable thermal overload relays 3UA series to protect system and motors against overload or phase-failure.They are made according to IEC947-2,BS5424 & VDE0660. The contactor is a straight...   >>
Add to My20un | User's Products | User's Profile | Contact
3TH Auxiliary Contactor
The auxiliary contactor is the auxiliary suited by controlled circuit whose voltage is AC 50/60Hz,660V and DC 660V.They control all kinds of magnetic coil and amplify or transfer signal to relative controlled element simultaneously.They are characterized by high performance & long service life.
3TH Auxiliary Contactor  2005-03-10 [China]  >> Expired
3TH Auxiliary Contactor The auxiliary contactor is the auxiliary suited by controlled circuit whose voltage is AC 50/60Hz,660V and DC 660V.They control all kinds of magnetic coil and amplify or transfer signal to relative controlled element simultaneously.They are characterized by high performance & long service life.   >>
Add to My20un | User's Products | User's Profile | Contact
3VL MCCB (Siemens Model)
3VL series MCCB is one of our new products developed and manufactured by adopting international advanced technology. It is supplied with rated insutaling voltage 690V and used for circuit of A.C.50/60Hz, rated operating voltage A.C. 415V or below, rated operating current from 16A to 250A. It is designed for protection of electric circuit, motors, transformers and other equipments. The products conforms to GB14048.4, IEC60947-1, IEC60947-2 & VDE0660 standards.
3VL MCCB (Siemens Model)  2005-02-28 [China]  >> Expired
3VL MCCB (Siemens Model) 3VL series MCCB is one of our new products developed and manufactured by adopting international advanced technology. It is supplied with rated insutaling voltage 690V and used for circuit of A.C.50/60Hz, rated operating voltage A.C. 415V or below, rated operating current from 16A to 250A. It is designed for protection of electric circuit, motors, transformers and other equipments. The products conforms to GB14048.4, IEC60947-1, IEC60947-2 & VDE0660 standards.   >>
Add to My20un | User's Products | User's Profile | Contact
Contact Select All Clear All
Previous12345678910Next